Electrical and Mechanical |
CPU |
i7, 2.53 GHz |
Memory |
4 GB |
Hard Disk |
8 GB Solid State Disk (up to 64GB optional). A removable solid-state disk for classified data storage is also optionally available |
Interfaces |
RS-422, RS-232, USB, Ethernet, VGA |
Display |
Optional sunlight-readable LCD sVGA display 600x800 resolution or a Tablet PC |
Control |
Optional touch-screen (part of display) |
Input Power |
One or three phase
105 VAC to 250 VAC
45 Hz to 420 Hz
800 W (max) input power |
DC Input power (Optional) |
28 VDC (750 W max input power) |
System Power (PXI Backplane) |
+5 VDC @ 35 A
+3.3 VDC @ 35 A
+12 VDC @ 3 A
-12 VDC @ 3 A
+19 VDC @ 5 A (for Tablet) |
Output Power (Auxiliary) |
28 VDC @ 1 A
5 VDC @ 1 A |
UUT Output Power (Optional) |
One DC/DC power supply brick, 240 W max, single or triple output |
Power Protection |
Over / Under Voltage
Over Current
Reverse Input DC Voltage
Over / Under Temperature |
Environmental* |
Operating Temperature |
-40 ºC to +63 ºC |
Storage Temperature |
-44 ºC to +71 ºC |
Relative Humidity |
95%, non-condensing |
Altitude |
15,000 ft (operating)
30,000 ft (non-operating) |
Loose Cargo Vibration |
IAW MIL-STD-810F, Method 514, Procedure II |
Vibration (Sine) |
IAW MIL-T-28800
Paragraph 4.5.5.3.2 |
Vibration (Random) |
IAW MIL-T-28800
Paragraph 4.5.5.3.1 |
Shock (Half-Sine) |
IAW MIL-T-28800
Paragraph 4.5.5.4.1
7G Operating
30G Non-Operating |
Salt Fog |
MIL-STD-810F, Method 509, Procedure I |
Dust |
MIL-STD-810F, Method 510, Procedure I |
Rain |
MIL-STD-810, Method 506, Procedure II |
EMI (Optional) |
MIL-STD-461E |
Cooling |
13 fans, 350CFM (max)
(temperature based speed control) |
Heating |
Built-in 345 W heater |
Size |
25" L x 19" W x 20" D |
Weight |
60 lb - basic; varies by configuration |
System Monitoring and Control - Smart Features* |
Control |
A dedicated microcontroller on the Power Board is capable of reading back measurements and controlling user I/O |
Temperature Monitoring |
2 sensors on Power Board (with readback)
8 sensors on the PXI backplane |
Voltage Monitoring |
PXI Power: +3.3 V, +5 V, +12 V, -12 V
+28 V (main), user DC / DC power supply |
Current Monitoring |
PXI Power: +3.3 V, +5 V
Rectified AC current, Fan current, user DC / DC power supply |
Frequency Monitoring |
AC Line Frequency (low resolution) |
Measurement Resolution |
8-bit |
Relay Control |
One optional 25 A 3PDT relay (socketed)
Two optional 10 A DPDT relay (socketed) |
User I/O |
32-bit, factory configurable as TTL or open-collector
4 groups of 8 with user direction control |
*Some environmental specifications require optional features such as heaters and EMI shielding. Note: Specifications are subject to change without notice.
Dynamic Digital Subsystem |
Configuration |
6U PXI format, (7) 32 channel DIO cards, (1) 16 channel DIO card,
programmable drive / sense per pin, 50 MHz vector rate (max) |
Number of Hyrid Channels |
224 |
Test Modes |
Dynamic or static |
Data Output Formats (per channel) |
Drive Hi, Drive Lo, Hi-Z
Formatted Data: No return, Return to 1, Return to 0, Return to Hi-Z, Return to complement, Surround by complement; selectable on a per channel basis |
Drive Data Timing (per channel) |
Data assert / de-assert based on Phases 1-4 |
Timing Sets |
256 Timing Set groups with 4 Phases, 4 Windows, and 4K sequence steps) |
Phase Programming Range (Assert/Return) |
0 ns to 64 us (using the 500 MHz master clock) |
Window Programming Range (Open/Close) |
0 ns to 64 us (using the 500 MHz master clock) |
Phase and Window Timing Resolution |
1 ns, using the 500 MHz master clock |
Capture Modes (per channel) |
Mask
Opening edge of Window
Closing edge of Window
Window – data is valid for entire window duration |
Drive/Expect Mode |
Output: Drive Hi, Drive Lo, Hi-Z
Expect: 1, 0, OK, between states, or mask
Keep last
Toggle last
Accumulate CRC-16 |
Error Address Record |
Record address for memory errors
1K deep error memory |
Drive Level Range |
-14 V to +26 V |
Drive Voltage Level Range |
Min: 0.5 V p-p
Max: 26 V p-p |
Drive Voltage Accuracy |
± 25 mv, < 26 V p-p drive voltage |
Sense Level Range |
-16 V to +22 V |
Maximum Sense Voltage Range |
26 V |
Sense Voltage Resolution |
16 bits |
Pull-Up/Pull-Down Current Source/Sink |
± 24 ma, programmable on a per channel basis
V commutate: -16 to +22 V., programmable on a per channel basis |
Pull-Up/Pull-Down Current Source/Sink Accuracy |
± 250 uA |
Pull-Up/Pull-Down Current Source/Sink Resolution |
16 bits |
Trigger/Clock Signals |
(4) Aux signals for external triggering, clocking of digital subsystem, accessible via the receiver interface and the IIP |
Mainframe Specifications |
Input AC Power |
120 / 208 VAC nominal, 3 phase, 5-wire wye configuration
20 A per phase, 47 to 63 Hz,
Input voltage range: 100 / 170 to 155 / 264 VAC |
HV Input AC Power Configuration |
230 / 400 VAC nominal, 3 phase, 5-wire wye configuration
10 A per phase, 47 to 63 Hz,
input voltage range: 223 / 380 to 310 / 528 VAC |
Total Available DC Power |
PXI voltages: 800 W
Pin electronics: 4.4 KW |
PXI Power |
+5 V
+3.3 V
+12 V
-12 V
Note: Total output power cannot exceed 800 W. |
60 A (max)
60 A (max)
25 A (max)
5 A (max) |
Pin Electronics (via P5 connector) |
VCC
VEE
3.3 V |
+2 V to +30 V, @ 50 A
-4 V to -18 V, @ 80A
3.3 V @ 60 A |
Power Supply Monitoring |
Monitored voltages: 3.3, 5, +12, -12, VIO value
Accuracy: ± 2% of reading |
Temperature Monitoring |
Per slot monitoring, 1 reading/sec/slot
4 second moving average value
User selectable alarm criteria:
- Maximum slot temperature
- Average slot temperature
Accuracy: ± 2 °C
Default warning and shutdown limits: +50 °C & +70 °C
Warning and shutdown limits programmable via software driver
Status: Query via software driver and audible alarm for a warning limit condition |
PXI Triggers |
Slots: 2 - 20
Number: 8 per segment
Software controlled segment mapping supports:
- Isolate a trigger line within a segment
- Map a trigger line left to right
- Map a trigger line right to left
|
PXI Clock |
Integrated 10 MHz PXI clock with auto-detect function. Presence of an external 10 MHz PXI clock will disable the internal clock. PXI clock is distributed to all peripheral slots.
- 10 MHz PXI clock accuracy: ±100 ppm
- External input: Rear panel (TTL compatible) or via timing slot
- Output: Rear panel, (TTL compatible)
|
Slots |
20 PXI or cPCI Slots (19 instruments max) |
Weight (core system) |
100 lbs |
Overall Dimensions |
10U (17.5") H x 19" W x 24" D |
Cooling |
Eight 100 CFM fans for system cooling. Integrated temperature monitoring via an on-board microcontroller with audible and software notification when preset temperature limits are exceeded. Fan speed control and monitoring is automatic and can be controlled / monitored via the GxChassis software. |
Environmental and Compliance |
Operating |
0 °C to +50 °C |
Storage |
-20 °C to +60 °C |
Relative Humidity (operating) |
5% to 80% RH,non-condensing |
Relative Humidity (non-operating) |
5% to 95% RH,non-condensing |
Altitude (operating) |
Up to 2000 M |
CE Compliance |
EN61010-1 (pending)
EN61326 (pending) |