广州虹科电子科技有限公司 虹科首页 | 电子测试 联系销售 技术支持
Active Technologies Active
Technologies
产品系列 > AT-LA500逻辑分析仪


附件


Probes

Active Technologies offers a wide range of probing options to support different measurement needs.

Active Hi-Z Probe: offers a linear input voltage range from -40V to +40V with 1.1MΩ of input resistance.
html Probe : offers a linear input voltage range from -38V to +38V with <10pF of input capacitance
and 130 MHz of toggle rate. 
Passive Probe: offers a linear input voltage range from 0V to 5V with 2V fixed threshold

4 Independent programmable thresholds allows you to test circuits with different logic families at the same time; 1 meter 
length probe cable provides an easy connection to boards under test even if they are far from the instrument

 

Active Hi-Z Probe:
Offers a linear input voltage range from
-40V to +40V with 1.1MΩ of input resistance.
Number of inputs 18 in two banks of 9.
Input capacitance 9 pF
Input resistance 1.1MΩ
Maximum toggle rate 80MHz
Linear input voltage range -40 to +40 V
Maximum input voltage -60 to + 60 V
Threshold voltage 2 programmable thresholds per probe, from -40V to +40V with 20mV step

html Probe:
Offers a linear input voltage range from
-38V to +38V with less than 10pF of input capacitance and 130 MHz of toggle rate. 
Number of inputs 18 in two banks of 9.
Input capacitance < 10 pF
Input resistance 22kΩ
Maximum toggle rate 130MHz
Linear input voltage range -38 to +38 V
Maximum input voltage -38 to +38 V
Threshold voltage 2 programmable thresholds per probe, from -38V to +38V with 20mV step

Passive Probe:
Offers a linear input voltage range from 0V to 5V with 2V fixed threshold
Number of inputs 18 in two banks of 9.
Maximum toggle rate 100MHz
Linear input voltage range 0 to +5 V
Maximum input voltage -3 to +6 V
Threshold voltage 2 V

AT-XSS:
AT-LA500 provides a dedicated expansion bus, called AT-XSS, for expandability and synchronization with external instruments (i.e. oscilloscopes). The synchronization is bidirectional so that the oscilloscope and the logic analyzer can be in turn the trigger master.
The BNC board provides a simple way to connect your oscilloscope with AT-LA500. BNC cables are not included.

AT-XSS (Extended Synchronous System) Cable provides a simple way to link up 8 AT-LAs to expand the number of channels with no loss of performance: up to 288 Channels @ 500 MS/s.
It is also possible to connect other AT test equipment instruments to create a measurement system.

 

AT-LA500逻辑分析仪 >

 

 

Email该网页 Email 本页

需要更详细资料?请通过sales@hkaco.com联系我们。

 

电子测试产品

AT产品
AT-LA500 USB逻辑分析仪
AT-AWG-GS 2500 PC任意波形发生器
AT-1120/AT-1212高速任意信号发生器NI-Flex RIO适配器模块
AT-VPX1000 OpenVPX板
其它品牌产品
PicoScope 6407高速USB数字化仪
PicoScope 2205混合信号示波器
PicoScope 3200系列示波器
PicoScope5000系列柔性分辨率示波器
PicoScope 6000系列示波器
PicoScope 9300系列采样示波器
OMEGA逻辑分析仪
SIGMA2逻辑分析仪

 

Email 新浪微博 博客 论坛 点击发送消息给我 

关于虹科虹科积极进取,不断探索科技新领域。最优秀的员工和最好的技术能够接受最困难的挑战。为您找到最佳解决方案。虹科靠口碑赢得客户。

广州:400 999 3848;13533491614;15986394530 | 上海:021-31215998 | 北京:010-57815068

sales@hkaco.com | 广州虹科电子科技有限公司 | 版权所有 | 广州市科学城神舟路18号润慧科技园C栋6层