Probes
Active Technologies offers a wide range of probing options to support different measurement needs.
Active Hi-Z Probe: offers a linear input voltage range from -40V to +40V with 1.1MΩ of input resistance.
html Probe : offers a linear input voltage range from -38V to +38V with <10pF of input capacitance
and 130 MHz of toggle rate.
Passive Probe: offers a linear input voltage range
from 0V to 5V with 2V fixed threshold
4 Independent programmable thresholds allows you to test circuits with different logic families at the same time; 1 meter
length probe cable provides an easy connection to boards under
test even if they are far from the instrument
Active Hi-Z Probe: |
Offers a linear input voltage range from
-40V to +40V with 1.1MΩ of input resistance. |
Number of inputs |
18 in two banks of 9. |
Input capacitance |
9 pF |
Input resistance |
1.1MΩ |
Maximum toggle rate |
80MHz |
Linear input voltage range |
-40 to +40 V |
Maximum input voltage |
-60 to + 60 V |
Threshold voltage |
2 programmable thresholds per probe, from -40V to +40V with 20mV step |
html Probe: |
Offers a linear input voltage range from
-38V to +38V with less than 10pF of input capacitance and 130 MHz of toggle rate. |
Number of inputs |
18 in two banks of 9. |
Input capacitance |
< 10 pF |
Input resistance |
22kΩ |
Maximum toggle rate |
130MHz |
Linear input voltage range |
-38 to +38 V |
Maximum input voltage |
-38 to +38 V |
Threshold voltage |
2 programmable thresholds per probe, from -38V to +38V with 20mV step |
Passive Probe: |
Offers a linear input voltage range from 0V to 5V with 2V fixed threshold |
Number of inputs |
18 in two banks of 9. |
Maximum toggle rate |
100MHz |
Linear input voltage range |
0 to +5 V |
Maximum input voltage |
-3 to +6 V |
Threshold voltage |
2 V |
AT-XSS: |
|
AT-LA500 provides a dedicated expansion bus, called AT-XSS, for expandability and synchronization with external instruments (i.e. oscilloscopes). The synchronization is bidirectional so that the oscilloscope and the logic analyzer can be in turn the trigger master.
The BNC board provides a simple way to connect your oscilloscope with AT-LA500. BNC cables are not included. |
|
AT-XSS (Extended Synchronous System) Cable provides a simple way to link up 8 AT-LAs to expand the number of channels with no loss of performance: up to 288 Channels @ 500 MS/s.
It is also possible to connect other AT test equipment instruments to create a measurement system. |